Arc Science

Omniverso

A generative model for designing antibody and nanobody binders, with antigen and epitope conditioning specified as a design.

Omniverso is a computational framework for the de novo design of antibody and nanobody binders. The base generative model, comprising an autoencoder and a flow-matching denoiser, is specified and implemented. A first training run comes next.

00Abstract

Omniverso addresses the challenge of de novo binder design against arbitrary antigens and epitopes. Generative models for antibody structures differ in conditioning, training data and evaluation, and their published success rates come from panels that are not matched. Omniverso introduces a partially latent flow-matching system designed for antibody and nanobody (Fv, VHH) binders. The system architecture includes an autoencoder and a denoiser learning velocity fields on coordinate and latent spaces. This document details the system specifications, data curation, training objectives, and evaluation protocols, including leakage-controlled splits and self-proteome specificity panels. The base generative model is implemented, providing a reproducible specification and codebase for antibody design.

01Representation

The model operates on a residue-centric representation, where each residue is defined by its C-alpha coordinates and an 8-number latent vector. This partially latent structure enables the model to learn and manipulate both structural and sequence-related information independently.

02Autoencoder

The autoencoder maps residue-level atom37 coordinates to a deterministic 8-number latent space. It comprises an encoder and a decoder, each with 12 blocks of width 768, totaling 255,873,676 parameters.

The decoder recovers residue types and atom positions from the latent representation and C-alpha coordinates. The autoencoder is implemented, allowing for deterministic encoding and reconstruction of structural data.

03Denoiser

The denoiser learns a velocity field that transports the residue stateβ€”C-alpha coordinates and latent vectorsβ€”from noise to data on independent timelines. It contains 14 blocks of width 768, totaling 153,102,091 parameters, including pair updates.

The architecture is configured for partially latent flow matching, enabling stable training from random initialization without pre-trained weights.

04Training objective

Training follows a partially latent flow-matching regime, where coordinate and latent paths are regressed on independent time-clocks towards a known target structure.

The velocity fields of both components are learned simultaneously. The training procedure includes a frozen encoder stage followed by denoiser training.

Two clocks

tx=2uβˆ’u2,tz=u2
u=0.00,tx=0.00,tz=0.00

Formula

Picture

Structure

Coordinates and latent values advance on separate clocks. Training draws the two times independently, and a sampler may walk one curve through the square of times.

From noise to a structure

πͺ0βˆΌπ’©(0,I)
πͺu=(1βˆ’u)πͺ0+uπͺ1
𝐛u=dπͺudu=πͺ1βˆ’πͺ0
tx=2uβˆ’u2
tx=2uβˆ’u2,tz=u2
vΞΈ(πͺu,u)β‰ˆπͺ1βˆ’πͺ0
β„’=𝔼‖vΞΈ(πͺu,u)βˆ’(πͺ1βˆ’πͺ0)β€–2
  1. Noise

    Each residue is described by eleven numbers: three place its alpha-carbon atom and eight form a learned latent vector. Training starts from random values of all eleven.

    The structure begins as random noise in the coordinate and latent spaces, much like sand grains scattered uniformly on a tray. Imagine a uniform gray fog where every point has an equal probability of being anywhere.

    Watch the uniform scattering of points.

  2. A straight path

    Flow matching joins a noise state to the state of a real structure by a straight line. The velocity along the line is constant, so the network learns it without solving a differential equation.

    The model learns a straight path from the noisy initialization towards the target data structure, ensuring a predictable transition. Think of a single particle sliding along a straight line at a constant speed from a chaotic starting position to its final ordered destination.

    See the flow arrows forming.

  3. Two clocks

    Coordinates and latent values advance on separate clocks. Training draws the two times independently, and a sampler may walk one curve through the square of times.

    Two independent time-clocks govern the transformation, one for spatial coordinates and another for latent identity. Imagine two separate stopwatches running side-by-side, where the physical coordinates settle into position before the latent identity fully resolves into its final state.

    Observe the dual progression.

  4. Regression

    At each intermediate state the network predicts the velocity. Its distance from the target, the end state minus the start state, is the training loss.

    Velocity fields guide the final regression, transforming noise into a coherent structural state through continuous adjustment. As the process unfolds, the points gradually snap into a defined structural form, turning the initial fog into an antibody binder.

    Points converging into structure.

05Data and splits

Training data consists of filtered structural complexes from the Protein Data Bank and AlphaFold DB. Leakage control is implemented through a multi-axis approach: antigen sequence (A1), structure (A2), epitope-residue Jaccard similarity (A3), and CDR-H3 identity (A4).

A temporal holdout (cut-off: 2025-01-01) further ensures strict separation between training and evaluation.

06Conditioning and steering

The full system integrates antigen conditioning, Interface-JEPA, and guided sampling through sequential Monte Carlo. Steering incorporates specificity panels for self-proteome cross-reactivity.

This conditioning architecture is specified for antibody (Fv) and nanobody (VHH) formats.

07Evaluation design

Evaluation employs standardized protocols comparing hit rates against published numbers. Specificity is assessed through a self-proteome panel, while developability leverages assays targeting expression, thermostability, and polyspecificity.

The protocol fixes leakage axes and comparison benchmarks in advance to ensure reproducibility.

08Compute

The training specification assumes a dual A100 configuration. Matrix-product operations determine the computational workload, with training checkpointing required for efficient execution.

Detailed TFLOP estimates are provided for sequence lengths of 300, 400, and 500 residues.

09Limits

The manuscript is a specification. The networks are built, training is the next step, and results and experimental validation follow from it. Its numbers are architecture values, computed quantities and targets. It makes no claim about binder binding, specificity, safety or accuracy. Only the base model is implemented: the autoencoder, the denoiser and the training code. Conditioning, steering, judging and selection are designs.

The denoiser is a transformer with no built-in rotational symmetry and uses no rotation augmentation, so it is not SE(3)-equivariant. Its 153,102,091 parameters are 3.7 % fewer than the 159 M reference network Proteina-Complexa. The manuscript makes no comparison with other systems, because published numbers come from panels that are not matched. The system relies entirely on computational prediction, and the manuscript and the three technical reports describe computational work only.

10System design

Partially latent flow-matching model architecture.

Reported figures
ValueWhat it isEvidence
255,873,676parametersAutoencoder, 12+12 blocks, width 768architecture
153,102,091parametersDenoiser, 14 blocks, pair update every layerarchitecture
8latent numbers per residueLatent width; flow state is 11 numbersarchitecture
48complexes per updateGlobal batch on two ranksarchitecture
2NVIDIA A100 40 GB cardsTraining configuration, one nodearchitecture
3.04, 5.26, 8.08TFLOP per complexDenoiser training work at 300, 400, 500 residuescomputed
88 to 92% of forward arithmeticPair update share; 2.4% of parameterscomputed
Cite

Danil Kotelnikov (2026). Omniverso: partially latent flow matching for de novo antibody and nanobody design. Manuscript, Arc Science.

entry
@misc
key
arcscience_omniverso2026
title
Omniverso: partially latent flow matching for de novo antibody and nanobody design
author
Danil Kotelnikov
year
2026
note
Manuscript, Arc Science

11Reports and papers

Source: this page. The attached reports hold the full text, tables and derivations.

  • OmniversoPDF 6.5 MB
    Abstract

    Omniverso designs antibody (Fv) and nanobody (VHH) binders for a chosen antigen and epitope. This volume (Technical Report I, Part I of the Omniverso Specification) covers the biological background, system layout, coordinate geometry, immunoglobulin contract and the anti-leakage data pipeline. It specifies the partially latent two-clock base model: an autoencoder with 255,873,676 parameters and a denoiser with 153,102,091 parameters, both for training from random initialisation. Supplementary Sections S2, S4 and S5 hold the data tables, the base-model training code and the compute derivations.

  • OmniversoPDF 2.4 MB
    Abstract

    Target-conditioned antibody generation has to keep coordinate symmetries while steering sampling towards affinity, structure and developability goals. This volume (Technical Report II, Part II of the Omniverso Specification) specifies antigen conditioning, Interface-JEPA scoring, guided sequential Monte Carlo sampling, and maturation through unbalanced optimal transport. Supplementary Section S1 gives the symbol dictionary and all 62 definitions, assumptions, propositions, lemmas, theorems, corollaries and proofs. The components beyond the unconditional base model are specified as a design.

  • OmniversoPDF 1.9 MB
    Abstract

    Pre-clinical candidate selection can fail through polyreactivity, immunogenic peptides, sequence liabilities or post-selection bias. This volume (Technical Report III, Part III of the Omniverso Specification) specifies complex judging, self-proteome specificity panels, clinical liability bands, and cautious scoring inside a Kullback-Leibler ball. It defines fixed-size portfolio selection committed before scores are read, conformal risk control and power calculations. Supplementary Section S3 holds the 53-gate falsification registry.

  • OmniversoPDF 3.4 MB
    Abstract

    Model, data, training and evaluation design, with the code of the base model

  • Omniverso
    Omniverso: supplementary informationDanil Kotelnikov, 108 pages
    PDF 5.9 MB
    Abstract

    Mathematics, data tables, evaluation protocol, code and computational budget